Urochem 299
POLYURETHANE SEALANT
DESCRIPTION
Urochem 299 is a two-component sealing compound based on a polyether polyurethane, blended with fillers and a chemical curing agent, which reacts after mixing to form a durable rubber like seal. This sealant is highly elastic and is able to withstand continuous extension and recovery. It may be used with most common building materials such as concrete, plaster, brick, and stone. It exhibits superior resistance to abrasion, ultraviolet light and ozone making it suitable for exterior use. Due to its excellent water resistance and adhesion plus resistance to biodegradation it forms the ideal material for use in sewage treatment plants.
JOINT DESIGN
- The recommended minimum joint dimension is 6 x 6mm, but where possible we recommend a 10 x 10mm joint.
- For joints ranging from 6mm to 10mm wide, we recommend a width to depth ratio of 1:1, for anything wider a 2:1 width to depth ratio should be maintained.
- In water retaining structures a 1:1 ratio should be maintained due to Hydrostatic pressure and cyclic movement.
- These ratios provide the optimum geometry to allow movement to occur within the joint without placing excessive force on the joint faces.
- Joint faces should be parallel, and the joint width should be at least four times the anticipated movement.
- When placing the sealant, the joint opening should if possible be central to its maximum compression/expansion cycle.
PRODUCT APPLICATION
- To form a long-lasting water and weatherproof seal in both horizontal and vertical moving joints and joints which are subject to continuous cyclic movement.
- Typical applications include joints in curtain walls, floor expansion joints, drainage channels and sewage treatment plants, between precast units and to seal pipe sections.
BOND BREAKER
To ensure correct movement of the joint a bond breaker must be used at the base of the joint. Where a backing material such as polyethylene foam rod is used to ensure the correct joint geometry a bond breaking tape is not required. For water retaining structures care must be taken to comply with design requirements set by the engineer.
APPLICATION
- Fill the sealant into a closed barrel gun using a follower plate or small trowel. Gun the sealant into the joint using a continuous squeezing of the trigger to ensure a smooth continuous flow of material. Fill the joint from the bottom up and ensure that there is contact between the sealant and joint surfaces.
- To ensure contact of the sealant with the walls of the joint, the sealant should be tooled to a smooth finish using a rounded spatula. A soapy solution may be used to aid the process. Remove any masking tape applied before curing commences.
SURFACE PREPARATION
The correct preparation of the joint faces is absolutely essential to the satisfactory performance of the sealant. All surfaces should be clean, sound, and dry, and laitance or surface contamination should be removed by thorough wire brushing, grinding or grit blasting. Vacuum or blow with compressed air to ensure thorough removal of dust. Metal surfaces should be free of mill scale and rust and mild steel treated with a suitable anticorrosive primer.
CLEANING
Clean all tools and equipment with Urochem 901 before setting of the sealant has taken place.
SAFETY
Contains organic solvents which are flammable. Do not use in confined spaces. Ensure adequate ventilation and the absence of any ignition source. Wear protective clothing. In case of eye contact wash well with water and obtain medical advice.
Please refer to product MSDS for further information.
PRIMING
- Urochem 102 Silane Primer should be used on glass, ceramics and sound masonry and brick surfaces not subjected to water immersion.
- Refer data sheet.
- Apply a single thin coat by brush and allow to dry for at least ten minutes before application of the sealant. If sealant is not applied after three hours re-prime. For water retaining structures, porous or friable surfaces or where severe conditions are expected use Urochem 101, 106 or 614. Mix base and activator thoroughly and apply the mixed material with a brush to the joint faces ensuring complete coverage. Particular attention should be paid to any voids and hollows. Allow at least 30 min. for the solvent to evaporate before applying the sealant.
- If after 3 hours or the primer loses its tack, re-prime.
- Protect the primed surface from dust and dirt, which could interfere with the adhesion of the sealant.
MIXING
- Urochem 299 is supplied in a two-part kit, base, and activator in separate tins.
- Transfer the total quantity of activator into the base component and mix thoroughly using a slow speed electric drill fitted with a flat blade stirrer.
- Scrape down the sides of the can and the base and remix until the colour is uniform and free from streaks.
- Thorough mixing is essential and should take 5 to 10 minutes.
TYPICAL PROPERTIES
Mixing Ratio
Two component – mix as supplied – Do not part mix
Pot Life
1 Hour @ 25° C
Tack Free
3 Days
Full Cure
7 Days
Colour
Grey – Colours available on order
Hardness
± 25 Shore A
Movement accommodation
+ 25%
Chemical resistance
Most dilute chemicals – Not aggressive chlorinated water
Density
1,53 g/cm³
Theoretical coverage
See Material Usage Guide below
Shelf Life
12 Months, depending on storage conditions
Application Temp.
5 – 35°C
Service Temp.
-10 – 90°C
Pack Size
2 Lt kits
Cleaning
Urochem 901
Storage
Store in a cool dry well ventilated place away from heat & sunlight
MATERIAL USAGE ESTIMATING GUIDE
(No allowance made for wastage)
CHEMICAL RESISTANCE